Door Key Cylinder Switch
- Remove door trim panel. Disconnect door key cylinder switch connector. Check continuity between door key cylinder switch terminals with door key cylinder in UNLOCKED position. If continuity exists, go to next step. If continuity does not exist, replace door key cylinder switch.
- Check resistance between door key cylinder switch terminals with door key cylinder in LOCKED position. Resistance should be 950-1050 ohms. If resistance is not as specified, replace door key cylinder switch.