LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 1997 >> Millenia Base >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel >> Component Testing >> Temperature Gauge

Temperature Gauge

NOTE: After changing checker resistance value, allow one minute for needle to stabilize.
  1. Remove instrument cluster. Connect battery positive voltage to terminal 2G (Black/Yellow wire) terminal of instrument cluster and ground terminal 2I (Brown/Red wire). SeeFig 1 . Connect Red wire of Checker (49-0839-285) to terminal 2E (Green wire) of instrument cluster. Connect checker Black wire to ground.
  2. Set checker to specified resistance value. See TEMPERATURE GAUGE RESISTANCE  . If temperature gauge needle does not rests at specified position for each resistance value setting, replace temperature gauge.
TEMPERATURE GAUGE RESISTANCE

Checker Resistance Setting (Ohms) Needle Position
155 (1) Cold
16.1 (2) Hot
(1) 175 ohms in cold regions.
(2) 20 ohms in cold regions.
Fig 1: Testing Temperature Gauge
G97I04498Courtesy of MAZDA MOTORS CORP.