Turn ignition off. Disconnect hydraulic unit harness connector. Using an ohmmeter, check resistance between specified terminals of ABS hydraulic unit connector. See Fig 1 . See HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE  table. If resistance is not as specified, check wiring harness. If wiring harness is okay, replace hydraulic unit.

HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE

Terminals Ohms
A & E 3
B & F 3
C & G 3
D & H 3
Fig 1: Identifying Hydraulic Unit 8-Pin Connector Terminals
G96F20235Courtesy of MAZDA MOTORS CORP.