Oxygen Sensor Testing Information (MT 0597-06)
Publication date: 1997-05-01Reference number: MT 0597-06
OXYGEN SENSOR TESTING INFORMATION
TECHNICAL INFORMATION TIP - MANUFACTURER
OXYGEN SENSOR TESTING
Model(s): 1995-97 Mazda B-Series
Category: Mazda Tips
Bulletin No.: MT 0597-06
Date: May, 1997
DESCRIPTION
Vehicles with EEC-V OBD II systems have oxygen sensors upstream and downstream of the catalyst.
Upstream oxygen sensors are used for fuel rate adjustment and operate the same as oxygen sensors in EEC-IV systems.
Oxygen sensors downstream of the catalyst are referred to as catalyst monitor sensors and are used to determine efficiency of the catalyst.
When monitoring the voltage of the downstream oxygen sensors, expect to see unpredictable voltage ranging from -0.1 to 1.5 volts. It is only during the catalyst monitor test that a predictable voltage switching occurs.
If a fault is detected during the downstream oxygen sensor monitor test, a DTC will be stored in continuous memory for later retrieval.