Turn ignition off. Disconnect hydraulic unit 8-pin connector. Using ohmmeter, measure resistance between specified terminals of hydraulic unit connector. See Fig 1 . See HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE . If resistance is not as specified, check wiring harness. If wiring harness is okay, replace hydraulic unit.
HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE
| Terminals | Ohms |
|---|---|
| A & E | 3 |
| B & F | 3 |
| C & G | 3 |
| D & H | 3 |