LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 1995 >> B3000 Base, Automatic >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System - Rear Wheel >> Component Testing >> RABS Valve Assembly >> Ground Circuit

Ground Circuit

Disconnect valve assembly connector. Using ohmmeter, check continuity between terminal No. 3 of valve assembly connector and ground. If continuity does not exist, repair valve assembly wiring harness.