Continuity Test

Disconnect 2-pin connector at hydraulic unit. Using a DVOM, check continuity between Red/Yellow wire terminal of 2-pin hydraulic unit connector and ground. If continuity is not present, replace hydraulic unit. If continuity is present, pump is okay. Check wiring between hydraulic unit and ABS control unit. Repair or replace if necessary.