Inspection (M/T)
- Disconnect TP sensor connector. Insert feeler gauge of specified thickness between throttle lever and throttle stop screw. See TP SENSOR CONTINUITY (M/T) table.
- Connect ohmmeter between specified terminals of TP sensor connector. See Figure. If continuity is not as specified, adjust TP sensor. See ADJUSTMENT procedure.