Test No. 6
Press horn pad. If horn does not sound, repair horn circuit. If horn sounds, measure voltage at terminal 2B (Green/Orange wire) of CPU No. 2 (8-pin connector). SeeFigure . If battery voltage is not present, repair wiring between horn relay and CPU No. 2. If battery voltage is present, replace CPU No. 2.