Crank Angle Sensor
Disconnect crank angle sensor connector. Connect circuit tester to crank angle sensor connector terminals. Check resistance between "G1" and "G2" terminals and "Ne1" and "Ne2" terminals. Resistance should be 110-210 ohms. See Fig 1.