LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 1987 >> 323 LX, Standard >> Repair and Diagnosis >> Electrical >> Starter >> Starter - Direct Drive >> Cranking Test Specifications >> Solenoid Tests >> Pull-In Test

Pull-In Test

Connect test leads to starter. See Figure. Connect negative leads to starter housing and "C" terminal. Battery positive lead is connected to terminal "50". If starter pinion gear does not move out, replace solenoid.