Water THERMO Valve: 626
- Remove water thermo valve. Connect a piece of tubing to each nipple. Immerse valve in container of water. Insert thermometer and slowly heat water.
- At temperature greater than 131°F (55°C) on 626, blow into one of the hoses. Air should pass through valve. If not, replace water thermo valve.