Valve Guide Servicing: Inspection
- Using dial indicator, check valve stem-to-guide clearance. Position dial indicator point about .40" (10 mm) above end of guide.
- Rock valve stem back and forth and measure movement. If clearance exceeds .0050" (.127 mm) replace valve and valve guide.