Pressure Test
- Remove air cleaner assembly and disconnect fuel line at carburetor. Connect suitable pressure gauge with restrictor and a flexible hose as illustrated in Figure.
- Turn ignition on and briefly vent the system into container by opening hose restrictor. Pressure should stabilize within specifications. If not within specifications and lines and filter are in satisfactory condition, pump must be replaced.