No. 1 Thermosensor
Disconnect wire connector and attach an ohmmeter as shown in illustration. When ambient and water temperatures are under 86°F (before engine warm-up), reading should be over 7, 000 ohms. When temperature is over 156°F (warmed engine), a reading of under 2300 ohms should be achieved.