Field Coils
Check for open or grounded coils using test lamp or voltmeter and battery connected in series. If any coil is defective, replace all coils. Mark housing and pole shoes for installation in original position. Remove pole piece screws and pry pole shoes, coils and insulation pieces from housing. To install, reverse removal procedure.