Pinpoint Test E : The BECMB (Extended Power Module) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2018 Ford F-550 Super Duty, 2018 Ford F-450 Super Duty, 2018 Ford F-350 Super Duty, and 2018 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
- E1 CHECK THE BECMB (EXTENDED POWER MODULE) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Wait one minute.
- Disconnect: BECMB C2518
- Ignition ON.
Is the voltage greater than 11 volts?
Yes GO to E2 No VERIFY BCM fuse 14 (10A) or fuse 35 (5A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the OEM Wiring Diagrams to identify the possible causes of the circuit short. - E2 CHECK THE BECMB (EXTENDED POWER MODULE) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C2518-1 Ground
Is the resistance less than 3 ohms?
Yes GO to E3 No REPAIR the circuit. - E3 CHECK THE HS-CAN1 (HIGH SPEED-CONTROLLER AREA NETWORK 1) CIRCUITS BETWEEN THE BECMB (EXTENDED POWER MODULE) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN
Are the resistances less than 3 ohms?
Yes GO to E4 No REPAIR the circuit in question. - E4 CHECK FOR CORRECT BECMB (EXTENDED POWER MODULE) OPERATION
- Ignition OFF.
- Disconnect and inspect the BECMB connector and related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the BECMB connector and related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new BECMB. Refer to: Battery Energy Control Module B (BECMB) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.