Remote Function Actuator (RFA) Module: Installation
- Install RFA
module.
- Connect the RFA
module electrical connectors.
- Tighten to 3 Nm (27 lb-in).
- Install the RH
side instrument panel hush panel.
- Connect the electrical connectors.
- Program the Intelligent Access (IA) keys (minimum of 2) into the new RFA
module. For additional information, refer to Key Programming Using Diagnostic Equipment in
ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS)
.
- Carry out the parameter reset between the RFA
module and the Body Control Module (BCM). For additional information, refer to Passive Anti-Theft System (PATS) Parameter Reset in
ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS)
.
- Download the RFA
module configuration information from the scan tool to the new RFA
module by following the scan tool on screen instructions.
- Turn the ignition ON.
- Carry out the keyless entry keypad code reset. For additional information, refer to Keyless Entry Keypad Code Programming in
HANDLES, LOCKS, LATCHES AND ENTRY SYSTEMS
.
- Carry out the RFA
module self-test to confirm all DTCs have been cleared.