Positive Crankcase Ventilation (PCV) System Components: Installation
- Install the PCV fitting and the 2 bolts.
- Tighten to 6 Nm (53 lb-in).
- Position the PCV tube and connect the quick connect couplings. For additional information, refer to FUEL SYSTEM - GENERAL INFORMATION .
- Position the air intake resonator assembly, install the bolt and the clamp.
- Tighten to 10 Nm (89 lb-in).