DTC Fault Trigger Conditions: Notes
DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
|
Generator Current Sensor Circuit Range/Performance | The PCM does not detect current through the generator current sensor and there are no generator current sensor circuit DTCs set. |
|
Generator Current Sensor Circuit Low | The PCM senses lower than expected voltage on the generator current sensor feedback circuit, indicating an open or a short directly to ground. |
|
Generator Current Sensor Circuit High | The PCM senses higher than expected voltage on the generator current sensor feedback circuit, indicating a short directly to voltage. |
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Generator current sensor
- PCM