Touchscreen Calibration
NOTE:
Recalibrate the touchscreen by following the scan tool prompts or the steps below.
- Make sure the vehicle battery is fully charged in order to avoid an inoperative touchscreen.
- Turn the ACM on.
- While in AM/FM mode, press and hold the EJECT button, and within 1 second, press the SEEK UP button.
- Press and hold the seek down button to enter the touchscreen calibration.
- Touch and hold the touch points as they appear on the touchscreen (a stylus is not required).
- When "New calibration settings have been measured. Press the Enter key to accept the new settings." is displayed, touch anywhere on the screen to accept the new settings.
- Clear all CMDTCs.