Principles of Operation: Notes
NOTE:
The Smart Junction Box (SJB) is also known as the Generic Electronic Module (GEM).
NOTE:
The time-out for the battery saver relay and the accessory delay relay (both are controlled by the SJB
) is 1 minute if the vehicle has less than 80 km (50 miles). Once the vehicle passes the approximate mileage threshold of 80 km (50 miles), the time-out for both relays is 10 minutes, as described in the Owner's Literature. For the battery saver relay, refer to
INTERIOR LIGHTING
. For the accessory delay relay, refer to
GLASS, FRAMES AND MECHANISMS
.
The SJB is a multifunction electronic module that controls many of the vehicle systems. Most of the SJB functions utilize hardwired inputs and/or outputs. The SJB controls the following hardwired functions, using the corresponding inputs and outputs:
FUNCTION TABLE
| Function | Input(s) | Output(s) |
|---|---|---|
| Accessory delay |
|
|
| Autolamps (if equipped) |
|
|
| Battery saver |
|
|
| Daytime Running Lamps (DRL) (if equipped) |
|
|
| Luggage compartment lid release |
|
|
| Fog lamps (if equipped) |
|
|
| Headlamps (low beam) |
|
|
| Headlamps (high beam and flash-to-pass) |
|
|
| Heated rear window |
|
|
| Horn |
|
|
| Parking lamps |
|
|
| Power door locks |
|
|
| Remote Keyless Entry (RKE) system |
|
|
| Stoplamps |
|
|
| Turn signal/hazard lamps |
|
|
The SJB is involved in other vehicle systems through communication over the Medium Speed Controller Area Network (MS-CAN). For a detailed list of SJB network inputs and outputs, refer to the Principles of Operation in MODULE COMMUNICATIONS NETWORK .
Some SJB parameters are programmable. Two types of programmable parameters are available: module configuration and programmable parameters. Refer to MODULE CONFIGURATION .