Remote Function Actuator (RFA) Module DTC Table
NOTE:
This module utilizes a 5-character DTC followed by a 2-character failure type code. The failure type code provides information about specific fault conditions such as opens or shorts to ground. CMDTCs have an additional 2-character DTC status code suffix to assist in determining DTC history.
DTC DESCRIPTION TABLE
| DTC | Description | Action |
|---|---|---|
| P0615:11 | Start Relay Circuit: Short to Ground | Go To PINPOINT TEST E . |
| P0615:12 | Start Relay Circuit: Short to Battery | Go To PINPOINT TEST E . |
| P0615:13 | Start Relay Circuit: Circuit Open | Go To PINPOINT TEST E . |
| All other DTCs | - | REFER to the DTC Table in MULTIFUNCTION ELECTRONIC MODULES . |