Temperature Blend Door Actuator
The temperature blend door actuator:
- is located on the heater core and evaporator core housing.
- moves the temperature blend door on command from the HVAC module.
- contains a reversible electric motor and a potentiometer. The potentiometer wiper is connected to the actuator output shaft and moves with the output shaft to indicate the position of the temperature blend door.
- applies a 5-volt signal to one end of the potentiometer and ground to the other. The voltage available at the wiper indicates the position of the potentiometer. The expressed value of the actuator wiper voltage is sent to the HVAC module and is matched with an expected wiper voltage value. The HVAC module then drives the actuator motor in whichever direction is necessary to make the actuator wiper voltage agree with the expected HVAC module wiper voltage value.