Home >> Lincoln >> 2006 >> Navigator 4WD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Handles, Locks, Latches And Entry Systems >> Diagnosis And Testing >> Locks, Latches and Entry Systems >> Pinpoint Tests >> Pinpoint Test L: The Remote Keyless Entry Transmitter Is Out Of Synchronization >> Pinpoint Test L: The Remote Keyless Entry Transmitter Is Out Of Synchronization

Pinpoint Test L: The Remote Keyless Entry Transmitter Is Out Of Synchronization

NOTE: All the remote keyless entry (RKE) transmitters must be present to begin diagnosis of the RKE system.
  1. L1 RESYNCHRONIZE THE INOPERATIVE RKE TRANSMITTER 
    • Key in OFF position.
    • Press any button on the inoperative RKE transmitter 4 times consecutively within 30 seconds.
    • Does the RKE transmitter operate correctly now? 

    Yes:  The system is OK. CLEAR the DTCs. REPEAT the self-test.

    No:  GO to  L2.

  2. L2 CHECK FOR A SECOND RKE TRANSMITTER 
    • Check for another RKE transmitter that operates with the vehicle.
    • Is there another RKE transmitter that operates with the vehicle? 

    Yes:  GO to  L3.

    No:  GO to  L4.

  3. L3 RESYNCHRONIZE THE INOPERATIVE RKE TRANSMITTER USING THE SECOND RKE TRANSMITTER 
    • Press any button on the operational RKE transmitter.
    • Within 30 seconds, press a button on the inoperative RKE transmitter.
    • Check the inoperative RKE transmitter for correct operation.
    • Does the inoperative RKE transmitter now operate? 

    Yes:  The system is OK. CLEAR the DTCs. REPEAT the self-test.

    No:  GO to  L4.

  4. L4 PROGRAM THE INOPERATIVE RKE TRANSMITTER OR ALL THE RKE TRANSMITTERS 
    • Program the inoperative RKE transmitter individually using a diagnostic tool or program all RKE transmitters using the manual key cycle method. Refer to REMOTE KEYLESS ENTRY TRANSMITTER PROGRAMMING .
    • Does the inoperative RKE transmitter now operate? 

    Yes:  The system is OK. INFORM the customer that any RKE transmitters not present need to be programmed. CLEAR the DTCs. REPEAT the self-test.

    No:  To diagnose the inoperative remote transmitter, GO to PINPOINT TEST H .