Component Testing Procedure
LUMBAR, SWITCHES COMPONENT TESTING
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Lumbar circuit | 5 and 1 | In | Closed circuit |
| Out | Open circuit | ||
| 4 and 3 | In | Closed circuit | |
| Out | Open circuit | ||
| 5 and 4 | In | Open circuit | |
| Out | Closed circuit | ||
| 1 and 3 | In | Open circuit | |
| Out | Closed circuit |