Mass Air Flow (MAF) Sensor
CAUTION:
The mass air flow (MAF) sensor electronics module and body are calibrated as a unit and must be serviced as a unit. Do not tamper with the sensing elements located in the air flow bypass of the MAF body.
- Disconnect the battery ground cable. For additional information, refer to BATTERY, MOUNTING AND CABLES .
- Disconnect the MAF sensor electrical connector.
- Disconnect the air cleaner outlet tube.
- Remove the 4 MAF sensor bolts.
- To install, tighten to 10 Nm (89 lb-in).
- Remove the MAF sensor and gasket.
- To install, reverse the removal procedure.