Vehicle Security Module C3008f

Fig 1: Identifying Vehicle Security Module C3008f Connector Terminals
G03860762Courtesy of FORD MOTOR CO.
VEHICLE SECURITY MODULE CONNECTOR TERMINALS REFERENCE

Pin Number(s) Circuit Designation/Description Normal Condition/Measurement
2 78 (LB/YE) remote keyless entry (RKE) keypad buttons 1/2, 3/4 and 5/6 input Less than 5 ohms between the RKE entry keypad and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
3 123 (RD) RKE keypad buttons 3/4 and 9/0 input Less than 5 ohms between the RKE keypad and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
4 124 (BN) RKE keypad button return Less than 5 ohms between the RKE keypad and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
6 66 (LB) RKE keypad illumination Less than 5 ohms between the RKE keypad and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
7 84 (VT/YE) liftgate window glass release actuator output Less than 5 ohms between the liftgate window glass release switch and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
8 664 (YE/LG) liftgate release actuator relay output Less than 5 ohms between the liftgate release relay and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
9 122 (YE) RKE keypad buttons 5/6 and 7/8 input Less than 5 ohms between the RKE keypad and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
10 913 (GY/RD) liftgate release switch input Less than 5 ohms between the liftgate release switch and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.
11 1092 (PK/OG) liftgate window glass release switch input Less than 5 ohms between the liftgate window glass release switch and the vehicle security module. Greater than 10,000 ohms between the vehicle security module and ground.