Item 5: TR Sensor Screws Installation Note
- Using the special tool, align the digital TR sensor and tighten the screws in an alternating sequence.
CAUTION:
Tightening one screw before tightening the other may cause the sensor to bind or become damaged.
NOTE:
The manual lever must be in the NEUTRAL position.