LEMON Manuals: Even more car manuals for everyone
Home >> Lincoln >> 2004 >> Aviator AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 268 (Climate Control System - General Information) >> General Procedures >> Manifold Gauge Set Connection

Manifold Gauge Set Connection

WARNING: This page is about a different car, the 2003 Lincoln Town Car. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Special Tool(s)
G01337912Courtesy of FORD MOTOR CO.
  1. Turn both valves on the R-134a Manifold Gauge Set clockwise to close the low- and high-pressure hoses to the center manifold and center hose.
    Fig 2: Closing Gauge Set Valves
    G01337913Courtesy of FORD MOTOR CO.
  2. Remove the A/C charging valve cap (19D702) from the low-pressure service gauge port valve.
    Fig 3: Removing Low-Pressure A/C Charging Valve Cap
    G01337914Courtesy of FORD MOTOR CO.
  3. Remove the A/C charging valve cap from the high-pressure service gauge port valve.
    Fig 4: Removing High-Pressure A/C Charging Valve Cap
    G01337915Courtesy of FORD MOTOR CO.
  4. Connect the R-134a Manifold Gauge Set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
    Fig 5: Connecting Low Side Quick Disconnect To Low-Pressure Service Gauge Port Valve
    G01337916Courtesy of FORD MOTOR CO.
  5. Connect the R-134a Manifold Gauge Set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.
    Fig 6: Connecting High Side Quick Disconnect To High-Pressure Service Gauge Port Valve
    G01337917Courtesy of FORD MOTOR CO.