Test M: No Module/Network Communication - No Power To NGS Tester
NOTE:
After making any repair, perform data link diagnostic test. See DATA LINK DIAGNOSTIC TEST under SELF-DIAGNOSTIC SYSTEM.
- Inspect NGS tester connector for loose, damaged or corroded terminals. Repair as necessary. If connector is okay, go to next step.
- Turn ignition switch to LOCK position. Inspect Data Link Connector (DLC) for loose, damaged or corroded terminals. Repair as necessary. If connector is okay, go to next step.
- Measure voltage between DLC terminal No. 16 (Light Blue/White wire) and ground. See Figure. If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, repair Light Blue/White wire between central junction box and DLC.
- Measure resistance between DLC terminal No. 4 (Black wire) and ground. Measure resistance between DLC terminal No. 5 (Black/White wire) and ground. If both readings are less than 5 ohms, repair or replace NGS tester. If any resistance reading is 5 ohms or more, repair open in Black wire or Black/White wire between ground and DLC.