Test D: Warning Indicator Off With Ignition On
Disconnect generator 3-pin connector. Connect a fused (15-amp) jumper wire between generator connector terminal "I" (Light Green/Red wire) and ground. With ignition on, observe warning indicator. If warning indicator illuminates, replace generator. See GENERATOR under REMOVAL & INSTALLATION. If warning indicator does not illuminate, repair warning indicator as necessary. See ANALOG INSTRUMENT PANELS - CONTINENTAL article in ACCESSORIES & EQUIPMENT.