Starter Specifications

BOSCH STARTER SPECIFICATIONS

Application Specification
Brush Length (New) .55" (14 mm)
Brush Spring Tension 64 Ozs. (18 N)
Commutator Runout .005" (.12 mm)
Maximum Load 800 Amps
Motor Current Draw Under Normal Load 130-220 Amps
Motor Minimum Stall Torque (5 Volts) 11 Ft. Lbs. (14.7 N.m)
No Load 60-80 Amps
Normal Engine Cranking Speed 140-220 RPM
Starter Diameter 3" (78 mm)
Starting Circuit Voltage Drop (1) .5 Volt (Max)
(1) Maximum voltage drop measured from battery positive terminal to starter terminal at normal engine temperature.