Wiring Continuity Check
Turn ignition off. Unplug EVO actuator valve harness connector. Check continuity of circuits No. 330 (Yellow/Light Green wire) and 353 (Light Blue wire) from EVO actuator valve harness connector to EVO control module pin No. 14. If continuity exists, proceed to QUICK TEST B4 . If continuity does not exist, service wires and go to QUICK TEST A1 .