Remove stator cap. Rotate choke thermostat lever clockwise until CER travel stop screw is bottomed on choke seal retainer (full travel). Dial indicator reading should be .490" (12.45 mm) at 0°F (-18°C). See Fig 1 . Adjust reading by turning screw with a 5/64" Allen wrench. Turn screw clockwise to decrease reading. Turn screw counterclockwise to increase reading.