Column Shift
- Place selector in Drive (Overdrive on AOT) position. Make sure selector lever remains against stop by hanging an 8 lb. (3.6 kg) weight on selector lever.
- Loosen shift rod adjusting bolt (or nut). Push manual transmission lever downward to lowest position (2nd detent from full counterclockwise position) or (3rd detent) for (AOT).
- Ensure the slotted rod end has flats aligned with flats on mounting stud (if equipped). Ensure selector lever has not moved from Drive (C-5) or Overdrive (AOT) position. Tighten bolt (or nut) and check operation in all selector detent positions. See Fig 1, Fig 2, and Fig 3.