Clearance Check
NOTE:
There are various gauges used for different size torque converters. Be sure to use the correct gauges.
- Insert applicable test tool into converter pump drive hub and bottom tool. Expand sleeve in turbine splines by tightening threaded inner post of test tool.
- Attach dial indicator to tool, rest indicator on converter pump drive hub. Zero dial gauge. Lift tool upward and note indicator reading.
- Reading is total converter and clearance. If clearance exceeds .021" (.53mm) new or rebuilt converter, or .040" (1.20mm) used converter, replace torque converter.