The minimum and maximum time for valve to reach 8 in. Hg vacuum should be as shown in following table:SPARK DELAY VALVE SPECIFICATIONS
| Application Color Code |
Time In Seconds Minimum |
Time In Seconds Maximum |
| Mono Delay Valve |
| |
1975-76 |
| |
|
Black/Gray |
1.0 |
4.0 |
| |
|
Black/Brown |
2.0 |
5.0 |
| |
|
Black/White |
4.0 |
12.0 |
| |
|
Black/Yellow |
6.0 |
14.0 |
| |
|
Black/Blue |
7.0 |
16.0 |
| |
|
Black/Green |
9.0 |
20.0 |
| |
|
Black/Orange |
13.0 |
24.0 |
| |
|
Black/Red |
15.0 |
28.0 |
| |
1977-79 |
| |
|
Black/Gray |
.6 |
1.6 |
| |
|
Black/Brown |
1.0 |
3.0 |
| |
|
Black/White |
3.0 |
9.0 |
| |
|
Black/Yellow |
4.5 |
13.0 |
| |
|
Black/Blue |
7.0 |
19.0 |
| |
|
Black/Green |
8.0 |
26.0 |
| |
|
Black/Orange |
11.5 |
38.0 |
| |
|
Black/Red |
14.0 |
47.0 |
| Retard Delay Valve |
| |
White/Pink |
2.7 |
9.3 |
| |
White/Brown |
1.O |
3.0 |
| |
White/Green |
8.0 |
26.0 |
| |
White/Yellow |
4.5 |
13.2 |
| |
White/Orange |
0.4 |
1.6 |
| Air Cleaner Delay Valve |
| |
White/Red |
14.0 |
47.2 |
| |
White/Blue |
8.0 |
26.0 |
| Dual Delay Valve |
| |
Brown |
1.0 |
3.0 |
| |
White |
2.7 |
9.3 |
| |
Yellow |
4.5 |
13.2 |
| |
Green |
8.0 |
26.0 |
| |
Red |
14.0 |
47.2 |