Pattern Select Switch
PATTERN SELECT SWITCH
| "NORMAL" or "NORMAL/CUSTOM" mode switch | ||
| Tester Connection | Condition | Specified Condition |
| 2 (NORM) - 6 (GND) | "NORMAL" or "NORMAL/CUSTOM" mode switch being pushed and held | 83.3 Ω or less |
| "NORMAL" or "NORMAL/CUSTOM" mode switch not pushed | 10 kΩ or higher | |
| "SPORT" or "S/S+" mode switch | ||
| Tester Connection | Condition | Specified Condition |
| 3 (SPSW) - 6 (GND) | Combination switch assembly knob turned and held at "SPORT" or "S/S+" position | 83.3 Ω or less |
| Combination switch assembly knob not turned to "SPORT" or "S/S+" position | 10 kΩ or higher | |
| "ECO" mode switch | ||
| Tester Connection | Condition | Specified Condition |
| 5 (ECU) - 6 (GND) | Combination switch assembly knob turned and held at "ECO" position | 83.3 Ω or less |
| Combination switch assembly knob not turned to "ECO" position | 10 kΩ or higher | |
| Illumination | ||
| Condition | Specified Condition | |
| Battery positive (+) → Terminal 4 (ILL+) Battery negative (-) → Terminal 1 (ILL-) |
Illuminates | |