Customize Parameters [08/2021 - ]
- CUSTOMIZE PRE-COLLISION SYSTEM NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Customizing with the Multi-information Display
- Turn the ignition switch to ON.
- Select the setting by referring to the table below.
- Using the steering pad switches, change the customize settings.
HINT:
Each item is displayed on the "Setting" tab on the multi-information display.
PRE-COLLISION SYSTEM SETTINGSDisplay Description Setting Default PCS Turns the pre-collision system function on/off. ON/OFF ON Warning sensitivity Sets the pre-collision system function warning sensitivity Early/Middle/Late Middle
- Customizing with the Techstream
- Select the setting by referring to the table below.
Others
Tester Display Description Default Setting ECU PCS Function ON/OFF State Stored Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 1 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 2 Refer to the table below Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 3 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera MEASUREMENT ITEMCustomize Setting Description Setting PCS Function ON/OFF State Stored Function to maintain the pre-collision system on/off setting when the ignition switch is turned to ON from off. Not stored: Pre-collision system always turns on
Stored: Pre-collision system maintains previous settingPCS Warning Timing State Stored 1 Function to set whether or not to store the warning sensitivity setting when the PCS function is turned from off to on while the ignition switch is ON. Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous valuePCS Warning Timing State Stored 2 Function to set whether or not to store the warning sensitivity setting when the PCS function is on and the ignition switch is turned from off to ON. Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous valuePCS Warning Timing State Stored 3 Function to set whether or not to store the warning sensitivity setting when the PCS function is off and the ignition switch is turned from off to ON. Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous value
- Select the setting by referring to the table below.