LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2023 >> LX 600 Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Stop And Start System - Diagnostic Codes (1 Of 2) >> Stop And Start System >> DTC P0606-29: Backup Boost Converter "A" Control CPU Signal Invalid [10/2023 - ] >> Procedure

DTC P0606-29: Backup Boost Converter "A" Control CPU Signal Invalid [10/2023 - ]: Procedure

  1. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BATTERY) 

    Pre-procedure1

    • Disconnect the engine stop and start ECU connector.
    • Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      B37-1 (BIN2) - Body ground Always 9.5 to 14 V
      B37-3 (BIN1) - Body ground Always 9.5 to 14 V

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BODY GROUND) 

    Pre-procedure1

    • Disconnect the engine stop and start ECU connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      B37-2 (GND2) - Body ground Always Below 1 Ω
      B37-8 (GND1) - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE ENGINE STOP AND START ECU. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR