LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2021 >> UX 250h Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (SFI) (M20A-FXS) - Diagnostic Codes (4 Of 6) (Hybrid) >> SFI System >> DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [10/2018 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

CASE 1

The following condition is met 2 data or more
One of the following conditions (a), (b) or (c) is met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent fault code Not stored
(c) Permanent fault code Not equal to commanded fault code
CASE 2

The following condition is met 2 data or more
Either of the following conditions (a) or (b) is met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent fault code Stored
CASE 3

Either of the following conditions is met 1 or 2
1. The following condition is met 2 data or more
EEPROM access error (more than 3 times) Occurred
2. Permanent fault code data (more than 10 times) Mismatch