LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2021 >> UX 200 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 45 (Motor Generator Control System (Diagnostics - Introduction)) >> Motor Generator Control System >> Definition Of Terms [10/2018 - ] >> Definition Of Terms [10/2018 - ]

Definition Of Terms [10/2018 - ]

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
Term Definition
Monitor Description Description of what the motor generator control ECU monitors and how to detects malfunctions (monitoring purpose and its details).
Related DTCs A group of diagnostic trouble codes that are output by the motor generator control ECU based on the same malfunction detection logic.
Typical Enabling Conditions Preconditions that allow the motor generator control ECU to detect malfunctions.
With all preconditions satisfied, the motor generator control ECU stores DTCs when the monitored value(s) exceeds malfunction threshold(s).
Sequence of Operation Order of monitor priority, applied if multiple sensors and components are involved in a single malfunction detection process.
Each sensor and component are monitored in turn and subsequent items are not monitored until the previous detection operation completes.
Required Sensors/Components Sensors and components used by the motor generator control ECU to detect each malfunction.
Frequency of Operation Number of times the motor generator control ECU checks for each malfunction during each driving cycle.
"Once per driving cycle" means that the motor generator control ECU only checks for malfunctions once during a single driving cycle.
"Continuous" means that the motor generator control ECU checks for malfunctions whenever enabling conditions are met.
Duration Minimum time for which the motor generator control ECU must detect continuous deviation in monitored value(s) in order to store a DTC. Timing begins when typical enabling conditions are met.
Malfunction Thresholds Value beyond which the motor generator control ECU determines malfunctions exist and stores DTCs.
MIL Operation Timing of MIL illumination after a malfunction is detected.
"Immediate" means that the motor generator control ECU illuminates the MIL as soon as a malfunction is detected.