DTC P0403-18: Exhaust Gas Recirculation "A" Circuit Current Below Threshold; DTC P040319: Exhaust Gas Recirculation "A" Circuit Current Above Threshold; DTC P140018: Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Below Threshold; DTC P140019: Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Above Threshold [10/2018 - 07/2022]: Description
Refer to DTC P040000.
Refer to DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P040318 | Exhaust Gas Recirculation "A" Circuit Current Below Threshold | Open or short in EGR A circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0489 |
| P040319 | Exhaust Gas Recirculation "A" Circuit Current Above Threshold | Short in EGR A circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0490 |
| P140018 | Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Below Threshold | Open or short in EGR B circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0489 |
| P140019 | Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Above Threshold | Short in EGR B circuit for 1 second or more (1 trip detection logic). |
|