Reverse Shift-linked Function of Power Mirrors does not Operate [01/2017 - ]: Procedure
- CHECK MEMORY AND REACTIVATION FUNCTION
- Turn the power switch on (IG).
- Using the multiplex network master switch assembly, turn the mirror surface to the fully left position.
- Press the M1 switch while the SET switch is being pressed.
- Check that the buzzer sounds for 0.5 seconds and the mirror surface position is memorized.
- Using the multiplex network master switch assembly, turn the mirror surface to the fully right position.
- Press the M1 switch.
- Check that the buzzer sounds for 0.1 seconds and the outer mirror automatically moves to the memorized fully left position.
Result
Result Proceed to Memory and reactivation functions are normal A Memory function is not normal B Reactivation function is not normal C
Result:
B
GO TO OTHER DIAGNOSTIC PROCEDURE (Power Mirror Surface Position is not Memorized). Refer to Power Mirror Surface Position is not Memorized [01/2017 - ]
Result:
C
GO TO OTHER DIAGNOSTIC PROCEDURE (Power Mirrors do not Return to Memorized Position). Refer to Power Mirror Surface Position is not Memorized [01/2017 - ]
Result:
A
See step 2
- CHECK FOR DTC (ELECTRIC SHIFT LEVER SYSTEM)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Hybrid Control / DTC.
- Check if electronic shift lever system DTCs are output.
Powertrain > Hybrid Control > Trouble Codes
OK
Electronic shift lever system DTCs are not output.
Result
Proceed to OK NG
Result:
NG
GO TO ELECTRONIC SHIFT LEVER SYSTEM. Refer to DIAGNOSTIC TROUBLE CODE CHART [01/2017 - 04/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [04/2020 - 05/2023] , or refer to DIAGNOSTIC TROUBLE CODE CHART [05/2023 - ]
Result:
OK
See step 3
- CHECK COMBINATION METER ASSEMBLY
- Check if the shift position indicator light in the combination meter assembly operates normally.
OK
Shift position indicator light indicates the actual shift position correctly.
Result
Proceed to OK NG
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [01/2017 - ]
Result:
OK
See step 4
- Check if the shift position indicator light in the combination meter assembly operates normally.
- CHECK REVERSE SHIFT-LINKED FUNCTION
- Turn the power switch on (READY).
- Turn the mirror select switch R or L switch on.
- Check that the mirror surface turns downward when the shift lever is moved to R.
Result
Result Proceed to Reverse shift-linked functions on both mirrors are not normal A Reverse shift-linked function on driver door is not normal B Reverse shift-linked function on front passenger door is not normal C
Result:
B
REPLACE FRONT MULTIPLEX NETWORK DOOR ECU LH. Refer to DISASSEMBLY [01/2017 - 06/2019] , or refer to DISASSEMBLY [06/2019 - 04/2020] , or refer to DISASSEMBLY [04/2020 - 05/2023] , or refer to DISASSEMBLY [05/2023 - ]
Result:
C
REPLACE FRONT MULTIPLEX NETWORK DOOR ECU RH. Refer to DISASSEMBLY [01/2017 - 06/2019] , or refer to DISASSEMBLY [06/2019 - 04/2020] , or refer to DISASSEMBLY [04/2020 - 05/2023] , or refer to DISASSEMBLY [05/2023 - ]
Result:
A
See step 5
- READ VALUE USING TECHSTREAM (MIRROR SELECTION SW (L), MIRROR SELECTION SW (R))
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Master Switch / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Master Switch > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Mirror Selection SW (L) Mirror select switch signal for LH mirror OFF or ON OFF: Mirror select switch off
ON: Mirror select switch L switch on- Mirror Selection SW (R) Mirror select switch signal for RH mirror OFF or ON OFF: Mirror select switch off
ON: Mirror select switch R switch on- Body Electrical > Master Switch > Data List
Tester Display Mirror Selection SW (L) Mirror Selection SW (R) OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
Result:
NG
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to REMOVAL [01/2017 - ]