DTC C1AB6: Blind Spot Monitor Master Module [01/2017 - ]: Procedure
- CHECK DTC
- Turn the power switch off.
- Turn the power switch on (IG).
- Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor Master > Trouble Codes
OK
No DTCs are output.
Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [01/2017 - 04/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [04/2020 - 05/2023] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [05/2023 - ]
Result:
NG
REPLACE BLIND SPOT MONITOR SENSOR RH. Refer to REMOVAL [01/2017 - ]