Inspection [08/2021 - ]: Procedure
- INSPECT CENTER CLUSTER MODULE SWITCH RH (HEIGHT CONTROL SWITCH)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Center Cluster Module Switch RH (Height Control Switch))Standard Resistance
Tester Connection Switch Condition Specified Condition 8 (LO) - 10 (GND) "Down" pressed 200 Ω or less "Up" pressed 10 kΩ or higher 3 (HI) - 10 (GND) "Down" pressed 10 kΩ or higher "Up" pressed 200 Ω or less If the result is not as specified, replace the center cluster module switch RH (height control switch).
- Apply battery voltage between the terminals of the center cluster module switch RH (height control switch), and check the illumination condition of the center cluster module switch RH (height control switch).
*a Component without harness connected
(Center Cluster Module Switch RH (Height Control Switch))Standard
Measurement Condition Specified Condition Battery positive (+) → 1 (ILL+)
Battery negative (-) → 5 (ILL-)Illuminates If the result is not as specified, replace the center cluster module switch RH (height control switch).
- Measure the resistance according to the value(s) in the table below.