Inspection [08/2021 - ]: Procedure
- INSPECT CENTER CLUSTER MODULE SWITCH RH (HEIGHT CONTROL OFF SWITCH)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Center Cluster Module Switch RH (Height Control OFF Switch))Standard Resistance
Tester Connection Switch Condition Specified Condition 2 (N) - 10 (GND) Height control OFF switch pressed 200 Ω or less Height control OFF switch not pressed 10 kΩ or higher If the result is not as specified, replace the center cluster module switch RH (height control OFF switch).
- Apply battery voltage between the terminals of the center cluster module switch RH (height control OFF switch), and check the illumination condition of the center cluster module switch RH (height control OFF switch).
*a Component without harness connected
(Center Cluster Module Switch RH (Height Control OFF Switch))Standard
Measurement Condition Specified Condition Battery positive (+) → 1 (ILL+)
Battery negative (-) → 5 (ILL-)Illuminates If the result is not as specified, replace the center cluster module switch RH (height control OFF switch).
- Measure the resistance according to the value(s) in the table below.