Power Source Mode does not Change to ON (IG) [12/2017 - 10/2023]: Procedure
- CHECK FOR DTC
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Smart Access, Power Source Control / Trouble Codes.
- Check for DTCs.
Body Electrical > Smart Access > Trouble Codes
Body Electrical > Power Source Control > Trouble Codes
Result
Result Proceed to DTCs are not output A Smart access system with push-button start (for Start Function) DTCs are output B
Result:
B
GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [12/2017 - 10/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2020 - 10/2022] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2022 - 10/2023]
Result:
A
See step 2
- CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
- Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Certification ECU (Smart Key ECU Assembly))Standard Voltage
Tester Connection Switch Condition Specified Condition G71-17 (IG1D) - Body ground Engine switch on (ACC) → Engine switch on (IG) 1 V or less → 9 V or higher Result
Proceed to OK NG
Result:
NG
REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY). Refer to REMOVAL [12/2017 - 09/2018] , or refer to REMOVAL [09/2018 - 10/2020] , or refer to REMOVAL [10/2020 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]
Result:
OK
See step 3
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY), POWER SUPPLY AND BODY GROUND)
- Disconnect the G71 certification ECU (smart key ECU assembly) connector.
- Disconnect the 5D, 5L and 5K instrument panel junction block assembly connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G71-17 (IG1D) - 5D-18 Always Below 1 Ω 5D-6 - Body ground Always Below 1 Ω G71-17 (IG1D) or 5D-18 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 5K-1 - Body ground Always 11 to 14 V 5L-1 - Body ground Always 11 to 14 V - Reconnect the G71 certification ECU (smart key ECU assembly) connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 D NO. 1, IG1 D NO. 2 AND IG2 D RELAY)
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [12/2017 - 09/2018] , or refer to REMOVAL [09/2018 - 10/2020] , or refer to REMOVAL [10/2020 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]
- Reconnect the instrument panel junction block assembly connectors.
*a Component with harness connected
(Instrument Panel Junction Block Assembly)- - - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition 5A-53 - Body ground Engine switch on (IG) 11 to 14 V 5D-32 - Body ground Engine switch on (IG) 11 to 14 V 5D-28 - Body ground Engine switch on (IG) 11 to 14 V 5H-10 - Body ground Engine switch on (IG) 9 to 14 V 5A-17 - Body ground Engine switch on (IG) 9 to 14 V Result
Proceed to OK NG
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2017 - 09/2018] , or refer to REMOVAL [09/2018 - 10/2020] , or refer to REMOVAL [10/2020 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]
Result:
OK
See step 5
- Remove the instrument panel junction block assembly.
- CHECK HARNESS AND CONNECTOR (PASSENGER SIDE JUNCTION BLOCK ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY, POWER SUPPLY AND BODY GROUND)
- Disconnect the 5A instrument panel junction block assembly connector.
- Disconnect the 4A, 4D, 4K and 4L passenger side junction block assembly connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 5A-17 - 4D-20 Always Below 1 Ω 4A-9 - Body ground Always Below 1 Ω 5A-17 or 4D-20 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4K-1 - Body ground Always 11 to 14 V 4L-1 - Body ground Always 11 to 14 V - Reconnect the 5A instrument panel junction block assembly connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 6
- CHECK PASSENGER SIDE JUNCTION BLOCK ASSEMBLY (IG1 P NO. 1, IG1 P NO. 2 AND IG2 P RELAY)
- Remove the passenger side junction block assembly.
Refer to REMOVAL [12/2017 - 10/2023]
- Reconnect the passenger side junction block assembly connectors.
*a Component with harness connected
(Passenger Side Junction Block Assembly)- - - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition 4A-49 - Body ground Engine switch on (IG) 11 to 14 V 4A-38 - Body ground Engine switch on (IG) 11 to 14 V 4A-20 - Body ground Engine switch on (IG) 11 to 14 V 4F-9 - Body ground Engine switch on (IG) 9 to 14 V 4F-10 - Body ground Engine switch on (IG) 9 to 14 V Result
Proceed to OK NG
Result:
NG
REPLACE PASSENGER SIDE JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2017 - 10/2023]
Result:
OK
See step 7
- Remove the passenger side junction block assembly.
- CHECK HARNESS AND CONNECTOR (LUG-IG1 NO. 1 RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY, POWER SUPPLY AND BODY GROUND)
- Disconnect the 5H instrument panel junction block assembly connector.
- Remove the LUG-IG1 NO. 1 relay.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 5H-10 - LUG-IG1 NO. 1 relay installation terminal 2 Always Below 1 Ω LUG-IG1 NO. 1 relay installation terminal 1 - Body ground Always Below 1 Ω 5H-10 or LUG-IG1 NO. 1 relay installation terminal 2 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition LUG-IG1 NO. 1 relay installation terminal 3 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 8
- INSPECT LUG-IG1 NO. 1 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω Battery voltage not applied between terminals 1 and 2 10 kΩ or higher *1 LUG-IG1 NO. 1 Relay Result
Proceed to OK NG
Result:
NG
REPLACE LUG-IG1 NO. 1 RELAY
Result:
OK
See step 9
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (LUG-IG1 NO. 2 RELAY - LUG-IG1 NO. 1 RELAY, POWER SUPPLY AND BODY GROUND)
- Remove the LUG-IG1 NO. 2 relay.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition LUG-IG1 NO. 1 relay installation terminal 5 - LUG-IG1 NO. 2 relay installation terminal 2 Always Below 1 Ω LUG-IG1 NO. 2 relay installation terminal 1 - Body ground Always Below 1 Ω LUG-IG1 NO. 1 relay installation terminal 5 or LUG-IG1 NO. 2 relay installation terminal 2 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition LUG-IG1 NO. 2 relay installation terminal 3 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 10
- INSPECT LUG-IG1 NO. 2 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω Battery voltage not applied between terminals 1 and 2 10 kΩ or higher *1 LUG-IG1 NO. 2 Relay Result
Proceed to OK NG
Result:
NG
REPLACE LUG-IG1 NO. 2 RELAY
Result:
OK
See step 11
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (IG2 RELAY - PASSENGER SIDE JUNCTION BLOCK ASSEMBLY, POWER SUPPLY AND BODY GROUND)
- Disconnect the 4F passenger side junction block assembly connector.
- Remove the IG2 relay.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4F-10 - IG2 relay installation terminal 1 Always Below 1 Ω IG2 relay installation terminal 2 - Body ground Always Below 1 Ω 4F-10 or IG2 relay installation terminal 1 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition IG2 relay installation terminal 3 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 12
- INSPECT IG2 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω Battery voltage not applied between terminals 1 and 2 10 kΩ or higher *1 IG2 Relay Result
Proceed to OK NG
Result:
NG
REPLACE IG2 RELAY
Result:
OK
See step 13
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (IG1 RELAY - PASSENGER SIDE JUNCTION BLOCK ASSEMBLY, POWER SUPPLY AND BODY GROUND)
- Remove the IG1 relay.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4F-9 - IG1 relay installation terminal 1 Always Below 1 Ω IG1 relay installation terminal 2 - Body ground Always Below 1 Ω 4F-9 or IG1 relay installation terminal 1 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition IG1 relay installation terminal 5 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 14
- INSPECT IG1 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω Battery voltage not applied between terminals 1 and 2 10 kΩ or higher *1 IG1 Relay Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2017 - 09/2018] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2018 - 10/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2020 - 11/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2021 - 10/2022] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2022 - 10/2023]
Result:
NG
REPLACE IG1 RELAY
- Measure the resistance according to the value(s) in the table below.