LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2019 >> GS 350 Base, AWD >> Repair and Diagnosis >> Steering >> Power Steering >> Variable Gear Ratio Steering System - Diagnostics - Introduction >> Variable Gear Ratio Steering System >> Data List / Active Test [09/2014 - ] >> Data List / Active Test [09/2014 - ]

Data List / Active Test [09/2014 - ]

HINT: 

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. DATA LIST 
    1. Turn the engine switch off.
    2. Connect the Techstream to the DLC3.
    3. Turn the engine switch on (IG).
    4. Turn the Techstream on.
    5. Enter the following menus: Chassis / VGRS / Data List.
    6. According to the display on the Techstream, read the Data List.
      VGRS

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Steering Angle Steering angle/
      Min.: -1638.40 deg
      Max.: 1638.35 deg
      -600 to 600 deg -
      Steering Angle Changing Speed Steering angle changing speed/
      Min.: -1638.40 deg/s
      Max.: 1638.35 deg/s
      -1146 to 1146 deg/s -
      Vehicle Speed Vehicle speed/
      Min.: 0.00 km/h (0 mph)
      Max.: 327.67 km/h (203 mph)
      Actual vehicle speed -
      Starting Status Starting status/
      Stop or Starting-up
      Engine stopped: Stop
      Engine running: Starting-up
      -
      IG Power Supply Voltage IG power supply voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      11 to 14 V -
      PIG Power Supply Voltage PIG power supply voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      11 to 14 V -
      Power Supply Status Power supply status/
      Normal, N Pos Stop, Cur Pos Stop or Prompt Stop
      Normal -
      System Heavily-loaded Status System heavily-loaded status/
      ON or OFF
      OFF -
      ECU Substrate Temperature ECU substrate temperature/
      Min.: -256.00°C (-428°F)
      Max.: 255.99°C (492°F)
      -40 to 120°C (-40 to 248°F) -
      Motor Temperature(ECU Calculated Value) Motor temperature/
      Min.: -256.00°C (-428°F)
      Max.: 255.99°C (492°F)
      Within 20°C (68°F) of ambient temperature -
      Ambient Temperature Ambient temperature/
      Min.: -40°C (-40°F)
      Max.: 50°C (122°F)
      Same as ambient temperature -
      System Overheat Status System overheat status
      Normal, Overheat-Weak, Overheat-Mid or Overheat-Strong
      Normal -
      ECU Substrate Temperature(ECU Calculated Value) ECU substrate temperature
      Min.: -256.00°C (-428°F)
      Max.: 255.99°C (492°F)
      -40 to 120°C (-40 to 248°F) -
      Wheel Angle(SIL Communication) Wheel angle (SIL communication)/
      Min.: -1638.40 deg
      Max.: 1638.35 deg
      -600 to 600 deg -
      Wheel Angle(CAN Communication) Wheel angle (CAN communication)/
      Min.: -1638.40 deg
      Max.: 1638.35 deg
      -600 to 600 deg -
      Steering Angle Sensor Communication Protocol Steering sensor communication protocol/
      Calc Val Fix, SIL or CAN
      SIL -
      Direct Advance Wheel Angle Direct advance wheel angle/
      Min.: -1638.40 deg
      Max.: 1638.35 deg
      -10.5 to 10.5 deg -
      Direct Advance Wheel Angle Status*1 Direct advance wheel angle status/
      Delete, Temp Val or Fixed Val
      Fixed Val -
      Motor Resolver Electrical Angle Motor resolver electrical angle/
      Min.: 0.00 deg
      Max.: 359.99 deg
      0.00 to 359.99 deg -
      Changing Amount of Motor Resolver Electrical Angle Changing amount of motor resolver electrical angle/
      Min.: -180.00 deg
      Max.: 179.99 deg
      -46 to 46 deg -
      Motor Resolver SIN Phase Shaped Width Motor resolver SIN phase amplitude/
      Min.: -5.00 V
      Max.: 4.99 V
      -4.1 to 4.1 V -
      Motor Resolver SIN Phase Offset Motor resolver SIN phase offset/
      Min.: 0.00 V
      Max.: 19.99 V
      5 to 15 V -
      Motor Resolver COS Phase Shaped Width Motor resolver COS phase amplitude/
      Min.: -5.00 V
      Max.: 4.99 V
      -4.1 to 4.1 V -
      Motor Resolver COS Phase Offset Motor resolver COS phase offset/
      Min.: 0.00 V
      Max.: 19.99 V
      5 to 15 V -
      Motor Resolver Shaped Width Squared Sum Sum of squares of motor resolver amplitudes/
      Min.: 0.00 V^2
      Max.: 25.00 V^2
      1.4 to 16.6 V^2 -
      Deep Groove Electrical Angle Position Deep groove electrical angle position/
      Min.: 0.00 deg
      Max.: 359.99 deg
      75 to 145 deg -
      Neutral Position Calibration Status Neutral position calibration status/
      Incmpl or Cmpl
      Cmpl -
      Actuator Target Angle Actuator target angle/
      Min.: -512.00 deg
      Max.: 511.98 deg
      -150 to 150 deg -
      Actuator Angle Actuator angle/
      Min.: -512.00 deg
      Max.: 511.98 deg
      -150 to 150 deg -
      Pinion Angle Status Pinion angle status/
      Invalid or Valid
      Valid -
      Pinion Angle Pinion angle/
      Min.: -2048.00 deg
      Max.: 2047.93 deg
      -600 to 600 deg -
      Motor U Phase Voltage Motor U phase voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      0 to 14 V -
      Motor V Phase Voltage Motor V phase voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      0 to 14 V -
      Motor W Phase Voltage Motor W phase voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      0 to 14 V -
      Motor U Phase Current Motor U phase current/
      Min.: -256.00 A
      Max.: 255.99 A
      -75 to 75 A -
      Motor V Phase Current Motor V phase current/
      Min.: -256.00 A
      Max.: 255.99 A
      -75 to 75 A -
      Motor W Phase Current Motor W phase current/
      Min.: -256.00 A
      Max.: 255.99 A
      -75 to 75 A -
      Motor U Phase Duty Motor U phase duty/
      Min.: 0.00 %
      Max.: 100.00 %
      6 to 94 % -
      Motor V Phase Duty Motor V phase duty/
      Min.: 0.00 %
      Max.: 100.00 %
      6 to 94 % -
      Motor W Phase Duty Motor W phase duty/
      Min.: 0.00 %
      Max.: 100.00 %
      6 to 94 % -
      PIG Current PIG current/
      Min.: -256.00 A
      Max.: 255.99 A
      -50 to 50 A -
      Motor Rotation Speed Motor rotation speed/
      Min.: -32768 deg/s
      Max.: 32767 deg/s
      -17190 to 17190 deg/s -
      Lock Solenoid Voltage Lock solenoid voltage/
      Min.: 0.00 V
      Max.: 255.99 V
      0 to 14 V -
      Lock Solenoid Duty Lock solenoid duty/
      Min.: 0 %
      Max.: 100 %
      0 to 100 % -
      Rear Target Wheel Angle*2 Rear target wheel angle/
      Min.: -8.00 deg
      Max.: 7.99 deg
      -2 to 2 deg -
      Rear Wheel Angle*2 Rear wheel angle/
      Min.: -8.00 deg
      Max.: 7.99 deg
      -2 to 2 deg -
      Actuator Operation Amount Actuator operation amount/
      Too Little, Normal, Malfunction or Too Much
      Normal -
      Number of DTC Number of DTCs recorded/
      Min.: 0
      Max.: 255
      0 -
      NOTE:

      *1: This data must be "Fixed Val" before proceeding with any steering adjustment. If "Delete" or "Temp Val" is displayed, perform the steering sensor initialization procedure. If the steering actuator assembly or VGRS ECU (front steering control ECU) has been replaced, perform VGRS system calibration (steering angle adjustment).

      HINT: 

      *2: w/ Dynamic Rear Steering System

  2. Abnormal Operation History 
    1. Turn the engine switch off.
    2. Connect the Techstream to the DLC3.
    3. Turn the engine switch on (IG).
    4. Turn the Techstream on.
    5. Enter the following menus: Chassis / VGRS / Data List / Abnormal Operation History.
    6. According to the display on the Techstream, read the Abnormal Operation History.
      VGRS

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Limited Control Count(Overheat-Weak) Limited control count (overheat-weak)/
      Min.: 0
      Max.: 255
      - The number of times which shows that overheat status of VGRS became "Overheat-Weak" and then the control was limited.
      Limited Control Count(Overheat-Mid) Limited control count (overheat-mid)/
      Min.: 0
      Max.: 255
      - The number of times which shows that overheat status of VGRS became "Overheat-Mid" and then the control was limited.
      Limited Control Count(Overheat-Strong) Limited control count (overheat-strong)/
      Min.: 0
      Max.: 255
      - The number of times which shows that overheat status of VGRS became "Overheat-Strong" and then the control was limited.
      N Pos Stop Control Count N pos stop control count/
      Min.: 0
      Max.: 255
      - The number of times which shows that power supply status to VGRS became "N Pos Stop" and then the control in "N Pos Stop" happened.
      Cur Pos Stop Control Count Cur pos stop control count/
      Min.: 0
      Max.: 255
      - The number of times which shows that power supply status to VGRS became "Cur Pos Stop" and then the control in "Cur Pos Stop" happened.
      Prompt Stop Control Count Prompt stop control count/
      Min.: 0
      Max.: 255
      - The number of times which shows that power supply status to VGRS became "Prompt Stop" and then the control in "Prompt Stop" happened.
      Limited Control Count(System Heavily-loaded) Limited control count (system heavily-loaded)/
      Min.: 0
      Max.: 255
      - The number of times which shows that VGRS system became heavily-loaded and then the control was limited.